NRG T60 Temperature Sensor

This next generation ambient temperature sensor builds on the NRG 110S’s trusted design, offering improved temperature accuracy and long-term reliability in harsh environments.

  4.6M CABLE (#9400) 13M CABLE (#9411) 67M CABLE (#9402) 90M CABLE (#9403) 110M CABLE (#9404) 13M CABLE - CALIBRATED (#9401)
Description
Sensor type Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield
Applications
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
Sensor range -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F)
Instrument compatibility All NRG loggers All NRG loggers All NRG loggers All NRG loggers All NRG loggers All NRG loggers
Output signal
Signal type Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage
Transfer function Temperature (°C) = (Voltage x 44.67629) -40.92151°C
Temperature (°F) = (Voltage x 80.53855) -41.53999 °F
Temperature (°C) = (Voltage x 44.67629) - 40.92151 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Temperature (°C) = (Voltage x 44.67629) - 40.92151 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.


Temperature (°C) = (Voltage x 44.67629) - 40.92151 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Temperature (°C) = (Voltage x 44.67629) - 40.92151 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Please refer to your calibration report.
Accuracy Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F)
Output signal range 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC
Turn on time <20 ms <20 ms <20 ms <20 ms <20 ms <20 ms
Resolution 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F)
Response characteristics
Thermal time constant 5.38 minutes 5.38 minutes 5.38 minutes 5.38 minutes 5.38 minutes 5.38 minutes
Power requirements
Supply voltage 5 to 15 V DC
5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
Supply current
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
Installation
Mounting Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps
Tools required
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
Environmental
Operating temperature range -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F)
Operating humidity range 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH
Lifespan 10 years + 10 years + 10 years + 10 years + 10 years + 10 years +
Other
  • IPX7 Rated
  • IPX7 Rated
  • IPX7 Rated
  • IPX7 Rated
  • IPX7 Rated
  • IPX7 Rated
Physical
Connections Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Cable length 4.6 m (15 ft) 13 m (42 ft) 67 m (220 ft) 90 m (295 ft) 110 m (361 ft) 13 m (42 ft)
Weight 0.47 kg (1.04 lbs) 0.75 kg (1.65 lbs) 2.53 kg (5.6 lbs) 3.29 kg (7.2 lbs) 3.94 kg (8.7 lbs) 0.75 kg (1.65 lbs)
Dimensions
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
Materials
Cable 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket
Probe Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled
Shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield

NRG Systems • 110 Riggs Road • Hinesburg, Vermont 05461 • +1 802-482-2255 • info@nrgsystems.com